TASSTA Documentation Center TASSTA Documentation Center More products
Hide table of contents Hide details Search My account

Configuring services

The section services in the provider's configuration allows you to tune up various services provided by the bridged network.

"services": {
    "lp": {
        "slot": 1,
        "request_interval": 60
    },
    "rrs": {
        "slot": 1,
        "request_interval": 60
    },
    "rcp": {
        "slots": [
            {
                "slot": 1,
                "ssi": [100, 101]
            }
        ]
    },
    "tmp": {
        "slots": [
            {
                "slot": 1,
                "ssi": [100, 101]
            }
        ]
    }
}

Although this section can be omitted, explicit configuration of service providers can speed up requests processing and reduce the load on the Hytera digital repeater from T.Bridge.

Location data provider

lp section configures real-time reporting of location data from bridged radios. Only applicable for mobile radios that support geolocation.

Parameter Description
slot Slot number, one of the predefined values:
  • 0 - try every available slot until succeed or ran out of slots (default);
  • 1 - first slot only;
  • 2 - second slot only.
Important: Explicitly specifying the slot number may speed up processing of location requests and reduce the load on the Hytera digital repeater.
request_interval The interval (in seconds) for periodically refreshing the radios' position.

Online / offline status provider

rrs section configures real-time checking whether bridged radios are online. See users_with_online_testing and users_without_online_testing for more information.

Parameter Description
slot Slot number, one of the predefined values:
  • 0 - try every available slot until succeed or ran out of slots (default);
  • 1 - first slot only;
  • 2 - second slot only.
Important: Explicitly specifying the slot number may speed up processing of status requests and reduce the load on the Hytera digital repeater.
request_interval The interval (in seconds) for periodically checking whether the radios are online.

Calls provider

rcp section explicitly sets call slots for bridged radios and channels.

"slots": [
    {
        "slot": 0,
        "ssi": [100, 101]
    },
    {
        "slot": 1,
        "ssi": [102, 103]
    },
    {
        "slot": 2,
        "ssi": [104, 105]
    }
]
Parameter Description
slot Slot number, one of the predefined values:
  • 0 - try every available slot until succeed or ran out of slots (default);
  • 1 - first slot only;
  • 2 - second slot only.
request_interval SSI's of mobile radios and channels for the slot.
Important:

The radios that are not directly specified in this section are automatically included in slot 0. It means the signal is sent to every available slot until succeed or ran out of slots.
It is recommended to configure this section to speed up requests processing and reduce the load on the Hytera digital repeater.

Messaging provider

tmp section explicitly sets messaging slots for bridged radios and channels.

"slots": [
    {
        "slot": 0,
        "ssi": [100, 101]
    },
    {
        "slot": 1,
        "ssi": [102, 103]
    },
    {
        "slot": 2,
        "ssi": [104, 105]
    }
]
Parameter Description
slot Slot number, one of the predefined values:
  • 0 - try every available slot until succeed or ran out of slots (default);
  • 1 - first slot only;
  • 2 - second slot only.
request_interval SSI's of mobile radios and channels for the slot.
Important:

The radios that are not directly specified in this section are automatically included in slot 0. It means the signal is sent to every available slot until succeed or ran out of slots.
It is recommended to configure this section to speed up requests processing and reduce the load on the Hytera digital repeater.